• Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions
  • Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions
  • Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions
  • Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions
  • Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions
  • Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions

Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions

After-sales Service: 6 Months
Warranty: 5years
Feature: Environmental, Fireproof, Light Weight, Waterproof, Sound Insulation, Heat Insulat
Fire Rating: 4
Certification: SGS TUV
Customized: Non-Customized
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Basic Info.

Model NO.
ZJT-F
Core
Sand, EPS, Cement, etc.
Size
60/75/80/90/100/120/150mm
Width
610mm
Length
2270mm/2440mm
Face Panel
Calcium Silicon Board
Main Features
Fireproof, Waterproof, Soundproof
Sound Insulation
32~56 dB
Heat Insulation
4 Hours Under 1000 Celsius Degree
Thermal Conductivity
0.221W/Mk
Fireproof
3~4 Hours
Transport Package
Plastic Thin Film, Edge Protect and Good Pallet
Specification
60/75/90/100/120/150mm
Trademark
ZJT
Origin
Fujian, China
HS Code
6810999000
Production Capacity
200000 Square Meters/Month

Product Description

 Lightweight Precast Concrete Wall Panels EPS Sandwich Panels as FPR Panels OSB Panel ICF Block
                                     


 

ZJT EPS Sandwich Panel

ZJT Light Composite Energy-saving Sandwich Wall Panel is composed of face panel and interior filling. The quality and technology of product have reached to a new level and become the leading brand among the similar products.

The product has solid, lightweight, thin, better strength, impact resistance, hanging strength, heat insulation, sound insulation, fireproof, waterproof, easy cutting, pet and rot resistant, increasing usable space. It can be arbitrary slot, without batch file, dry operation, enviroment protection, which achieve energy conservation and energy efficiency. At the same time, it reduces the total area to be occupied by the wall and to raise residentiand a new breakthroughal practical area,alleviates the structure load,improves the building aseismatic capacity and safety performance,and reduces your  total cost. Our production technology and application is the practice and a new breakthrough of  reform of our country wall material policy .
Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions

Wall Panels Advantages

  • Rapid construction specifically designed for use in remote areas where less skilled labor.
  • Can be used for multi-storey buildings.
  • With ingredients that have been tested scientifically, helping audiepanel walls that can withstand earthquakes.
  • Much lighter than the other conventional bricks.
  • Without plastering and smoothing walls, these products only need one day to erect a wall measuring 50m² and in just half a day.
  • Workers can instantly paint the walls after the installation.

 

Wall Panels Application                                          

Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions

 

Wall Panels Parameter                                             


 

  Item Testing Indexes
  Model (Thinkness/mm) 60mm 75mm 90mm 120mm 150mm
1 Anti-impact Capacity
[Standard sandbags/times]
≥5 ≥5 ≥5 ≥5 ≥5
2 Anti-bending Damage Load 
[times over deadweight]
≥3.0 ≥3.0 ≥3.0 ≥5.0 ≥5.0
3 Compressive Stregth [Mpa] ≥3.5 ≥3.5 ≥3.5 ≥3.5 ≥3.5
4 Softening Coefficient ≥0.8 ≥0.8 ≥0.8 ≥0.8 ≥0.8
5 Surface Density [kg/] ≤70 ≤70 ≤90 ≤110 ≤110
6 Moisture Rate [%] ≤10 ≤10 ≤10 ≤8 ≤8
7 Drying Shrinkage Value [mm/m] ≤0.5 ≤0.5 ≤0.5 ≤0.5 ≤0.5
8 Hang Force [N] ≥1000 ≥1000 ≥1000 ≥1000 ≥1000
9 Sound Insulation Capacity In the Air[dB] ≥35 ≥35 ≥40 ≥45 ≥50
10 Fire Endurance [H] ≥1.5 ≥1.5 ≥2.5 ≥3.0 ≥4.5
11 Heat Transfer Coefficient [W/m2.k] ≤2.0 ≤2.0 ≤2.0 ≤2.0 ≤2.0
12 Inner Radiation Index ≤1 ≤1 ≤1 ≤1 ≤1
13 Outer Radiation Index ≤1 ≤1 ≤1 ≤1 ≤1


Loading Information

Items(mm) Single(piece) Load by 20'GP Load by 40'GP
Kg/pcs Kg/m2 Qty(pcs) m2 Tons Qty(pcs) m2 Tons
2270×610×60 0.08 47 34 313 433 15 525 727 26
2270×610×75 0.10 67 48 252 349 17 364 504 26
2270×610×90 0.12 77 56 207 287 16 322 446 26
2270×610×100 0.14 87 63 189 262 18 280 388 26
2270×610×120 0.17 98 71 162 224 16 252 349 26
2270×610×150 0.21 147 106 126 174 18 147 204 26
 
2440×610×60 0.09 60 40 240 357 15 420 625 26
2440×610×75 0.11 80 54 204 304 17 308 458 26
2440×610×90 0.13 90 60 168 250 16 336 500 26
2440×610×100 0.15 100 67 144 214 15 240 357 26
2440×610×120 0.18 110 74 108 161 12 216 321 26
2440×610×150 0.22 160 107 78 116 16 156 232 26

Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions

    How to install 

    1. lift plate
    In the wall and floor mounting portion projectile base or bottom end of the beam perpendicular to the baseline, to ensure that the installation wall verticality and flatness, and identifies the position of the door opening; rear wall to enter the scene, or using the machine according to the plate thickness of the plate is carried mounted on the wall portion.

    2. Saws
    The specifications for the wall entire board width 610mm, length 2440mm. When the end panels is less than a width or height of the entire board should be used up plate, with a hand-held unit according to claim any cutting, and the length of the wall to adjust the width of the wall panels loss rate. groove brush with water and wet wallboard, and then the polymer mortar caulking professional wallboard groove flooring inside the baseline.

    3. Sizing
    Professional installation with water in proportion to the sealing paste was slurried, then wiped clean with a damp cloth dust wall surface irregularities grooves, tongue.

    4. Plates
    After the mortar wall moving means Shanghao fight like bit position, standing vertically on good baseline, with a crowbar to pry from the bottom wall, so that the force against the plate between the plate and the polymer mortar from a seam extruded and then scraped wall panel projecting a slurry, the slurry must ensure that the seam between the plate and the plate is full, and finally by temporarily fixing the wedge.

    5. Proofreading
    After initially siding assembled good, use a crowbar professional conduct tone correction, with smooth straight by foot inspection, verticality of 2M.

    6. Fixed
    After installation calibration, with temporary fixing wedge wall, and floor (bottom and top), in addition to the adhesive polymer cement mortar two panels, vertical panels connected to adjacent like, but also the application of 200 ~ ○ 250mm length 6 8 as reinforcement or strengthening treatment (reinforced inserted inside wall should be greater than 100mm). 125mm or more thick steel slab must into two.

    7. Pointing processing
    After installing the panels with the above joint materials, joint mortar scrape convex wall panel, and a seam tick mouth, generally not less than board 4 ~ 5mm, this stepis for seaming wall panels and consider.

    8. Grouting
    Wall mounting process will start seven days after the completion of maintenance of good professional slurry filling the wall with polymer, the joint between the board and the board and the slits, and the original pull wedge filled with mortar.
    1), Preceded remove dust filling the joint surface, then the blade caulking materials are triggered by full embedded wallboard joint port; A step of processing in order to start the joint.
    2), Wait 6 to 8 hours to complete the slurry.

    9. Buried conduit
    Buried conduit inner wall, the switch socket box,the installation of water depending on design requirements disposable unit shown in the wallboard all strong, weak, and all kinds of water supply and drainage ducts line, box, cartridge position, not at the same at the same time slot position on both sides of the opening hole, and the conservation of the wall should be carried out after a minimum of three days. In cases where the same position on both sides of the wall while the wiring pipe, casing, switch boxes, should be shifted in a horizontal direction or a height direction of 100mm or more, so as not to reduce the sound insulation wall. When the slot, the width should be good to play the slot size, and with a (small) cut out border Portable cutting machine, and then the artificial light gouges, rigorous violence slotted openings, generally not more than the depth of gouges wall thickness 2/3 of the width of not more than 400mm. Embedding mode and Line Pipe Specification perform the requirements, to the level of the conduit should not exceed 350mm, polymer cement mortar stratified slab according to backfill the processing line handling the well pipe burial.

    10. A joint (crack tape joining) process
    Process should be conducted after the seam doors,window frames, pipe installation (not less than 7 days). First clean the seam area, fill up the pore damaged, clean surface, and then paste the seams crack with construction, and follow these steps:
    1), should remove dust attached to the front surface of the joint with crack;
    2), the maintenance and the like grout slurry was completely dry, with more than 50mm wide crack fiber mesh tape stuck on the white latex paste slit, and compacted with a scraper along the seams, scrape excess white latex;
    3), fiber mesh Once dry, then more than 100mm wide crack fiber mesh or perforated paper with white tape attached to stick to the slit latex, and compacted with a scraper along the seams, scrape excess white latex and removing bubbles taken off the grid;
    4), the mesh belt after the other joints (punched tape) completely dry, can be according to design requirements (e.g. plaster) of the wall construction of the surface finish.

    Contact Info

    Freda Lin
    Lightweight Precast Concrete/ Structural Insulated Wall Panel/ EPS Sandwich Panel as Room Divider/ Room Partition/ Wall Dividers/Office Partitions


     

     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now

    You Might Also Like

    Diamond Member Since 2014

    Suppliers with verified business licenses

    Management System Certification
    ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, OHSAS/ OHSMS 18001, IATF16949, HSE, ISO 14064, QC 080000, GMP, BSCI, BRC, SA 8000, QHSE, HACCP, BS 25999-2, ISO 13485, EICC, ANSI/ESD, SEDEX, ISO 22000, AIB, WRAP, GAP,ISO 29001, BREEAM, HQE, SHE Audits, IFS, QSR, ISO 50001, LEED, PAS 28000, FSC, ISO 10012, ISO 17025
    OEM/ODM Availability
    Yes